      When new tabs/windows are opened to same application the blocking connection can change the owning window. When this occurs the heartbeat of the window that used to own the blocking connection does not shutdown its heartbeat. As a result pings are send by all the windows that used to own the blocking connection at some point in time.

        Activity

        Hide
        Mircea Toma added a comment -

        Shutdown the heartbeat of the bridge instance when the server requests a shutdown of the blocking connection (marked by the X-Connection custom header).

        Show
        Mircea Toma added a comment - Shutdown the heartbeat of the bridge instance when the server requests a shutdown of the blocking connection (marked by the X-Connection custom header).