ICEfaces
  1. ICEfaces
  2. ICE-4933

Heartbeat not shutdown when blocking connection switched to a different bridge instance

    Details

    • Type: Bug Bug
    • Status: Closed
    • Priority: Major Major
    • Resolution: Fixed
    • Affects Version/s: 1.8.1
    • Fix Version/s: 1.8.2-RC1, 1.8.2
    • Component/s: None
    • Labels:
      None
    • Environment:
      supported browsers

      Description

      When new tabs/windows are opened to same application the blocking connection can change the owning window. When this occurs the heartbeat of the window that used to own the blocking connection does not shutdown its heartbeat. As a result pings are send by all the windows that used to own the blocking connection at some point in time.

        Activity

        Repository Revision Date User Message
        ICEsoft Public SVN Repository #19249 Mon Sep 14 13:18:31 MDT 2009 mircea.toma ICE-4933 Shutdown the heartbeat of the bridge instance when the server requests a shutdown of the blocking connection.
        Files Changed
        Commit graph MODIFY /icefaces/trunk/icefaces/bridge/src/connection.async.js
        Mircea Toma created issue -
        Mircea Toma made changes -
        Field Original Value New Value
        Salesforce Case []
        Fix Version/s 1.8.2 [ 10190 ]
        Assignee Mircea Toma [ mircea.toma ]
        Mircea Toma made changes -
        Salesforce Case []
        Description When new tabs/windows are opened to same application the blocking connection can change the owning window. When this occurs the heartbeat of the window that used to own the blocking connection does not shutdown its heartbeat. As a result pings are send by all the windows that used to own at some point in the blocking connection. When new tabs/windows are opened to same application the blocking connection can change the owning window. When this occurs the heartbeat of the window that used to own the blocking connection does not shutdown its heartbeat. As a result pings are send by all the windows that used to own the blocking connection at some point in time.
        Hide
        Mircea Toma added a comment -

        Shutdown the heartbeat of the bridge instance when the server requests a shutdown of the blocking connection (marked by the X-Connection custom header).

        Show
        Mircea Toma added a comment - Shutdown the heartbeat of the bridge instance when the server requests a shutdown of the blocking connection (marked by the X-Connection custom header).
        Mircea Toma made changes -
        Status Open [ 1 ] Resolved [ 5 ]
        Resolution Fixed [ 1 ]
        Ken Fyten made changes -
        Fix Version/s 1.8.2-RC1 [ 10210 ]
        Ken Fyten made changes -
        Status Resolved [ 5 ] Closed [ 6 ]

          People

          • Assignee:
            Mircea Toma
            Reporter:
            Mircea Toma
          • Votes:
            0 Vote for this issue
            Watchers:
            0 Start watching this issue

            Dates

            • Created:
              Updated:
              Resolved: