Details
-
Type: Bug
-
Status: Closed
-
Priority: Major
-
Resolution: Fixed
-
Affects Version/s: 3.2
-
Fix Version/s: EE-3.2.0.BETA, EE-3.2.0.GA, 3.3
-
Component/s: Bridge
-
Labels:None
-
Environment:IE8
Description
Just before the DOM updates are applied the bridge tries to cleanup the event handlers of all the elements that will be gone once update is applied. The cleanup can take a significant amount of time (> 10 seconds) when the updates have a large number of elements.
Modified findAndNotifyUpdatedElements function to use properties on object to define key-value pairs instead of using the Cell object defined in collections.js. This implementation change speeds up the execution since accessing properties on an object is much faster than using the single method dispatch mechanism used by the Cell object.