Details
-
Type:
Bug
-
Status: Closed
-
Priority:
Major
-
Resolution: Fixed
-
Affects Version/s: 4.1
-
Fix Version/s: 4.2
-
Component/s: ICECORE-Components, Sample Apps
-
Labels:None
-
Environment:showcase icecore:refresh > Overview demo, tomcat 7/8, ICEfaces 4 trunk r53707, myfaces 2.2.12
-
Assignee Priority:P2
Description
showcase icecore:refresh > Overview demo.
Load the page then the clock stops after one tick. All browsers. Myfaces specific issue.
Load the page then the clock stops after one tick. All browsers. Myfaces specific issue.
Modified RefreshHandler to add the refresh setup as a non-transient component to the tree to ensure that the component is always restored during post-backs (including the extra steps done by Myfaces when REFRESH_TRANSIENT_BUILD_ON_PSS parameter is enabled).